Most inflatable tubs plug into a 13 A socket with a heater of about 2.0 to 2.2 kW. Heating from cold takes many hours; keeping the water warm under a good cover costs far less than heating it again.

Typical heater
2.0 to 2.2 kW
Usual maximum
40 °C

Heating water takes a fixed amount of energy: 1 litre warmed by 1 °C needs about 4.186 kJ. For 800 litres from 10 °C to 38 °C that is about 26 kWh before any losses, or roughly 12 hours at 2.2 kW. The heat-up calculator does the sum with your own unit rate in p/kWh.

Real times are longer, because heat escapes through the walls, the cover and the air, more so on cold or windy days and with the bubbles running. Keeping the cover on, adding a floor mat and sheltering the tub from wind all help.

Use a dedicated outdoor socket where possible and follow the maker's instructions on extension leads and RCD protection. Some tubs cannot run the heater and the bubbles at the same time on a 13 A supply.

Common mistakes

  • Using the maker's heating rate per hour as if it held in a British winter.
  • Leaving the cover off for long spells while the heater runs.
  • Copying a running cost figure from someone else's tariff instead of using your own p/kWh.